Key Features
High power density with 5000VA/4500 Watts of power packed in just 3U rack space
Greater system uptime with support for Extended Runtime Modules (ERM)
Easy configuration through enhanced front panel display
Enterprise-wide intelligent manageability with bundled UPS Network Module and HP Power
Protector software
More efficient voltage regulation with revolutionary Digital Signal Processing technology
Ultimate long-term battery reliability with HP Enhanced Battery Management
Enhanced system flexibility with two independently controlled load segments
Support for Remote Emergency Power Off (REPO) circuitry
Easy serviceability through modular design
Hot-Swappable Battery
Backed by a three year warranty with the first year including parts and labor. HP's Pre-Failure
warranty, and a $250,000 load protection guarantee. (Certain restrictions and exclusions apply)
Optional Extended Runtime Modules (ERM) increase batter runtime during a power failure
3U Power Packed Design
Rated near unity at 5000VA / 4500W, the HP UPS R5000 packs more power in space-conserving rack-
mount design, allowing you to support more critical equipment in your rack.
Increase System Uptime
with Extended Runtime
Modules
The Extended Runtime Modules are rack mounted battery modules that occupy 3U (5.25 inches) of rack
space. The HP UPS R5000 supports up to four Extended Runtime Modules (ERM), which extends your
overall battery runtime.
Lower Cost of Ownership
with Innovative
Technology
The HP UPS R5000 utilizes a new industry-leading technology that continually conditions and regulates
power without using the battery, thereby increasing the life of the battery. The output voltage is
automatically regulated, based on the connected load and the input voltage.
Investment Protection
with HP Enhanced Battery
Management
HP UPS R5000 incorporates Enhanced Battery Management: an exclusive, patented technology that
doubles battery service life, optimizes battery recharge time, and provides advance notice of pending
battery failure. With Enhanced Battery Management, you can save 2-3 battery replacements over the life
of the UPS saving hundreds of dollars giving you a lower total cost of ownership while still receiving the
power protection for your critical equipment.
Enhanced Flexibility
Four C13 outlets, four C19 outlets, and a L6-30 outlet provide a wide range of connection options. Adding
the HP PDU Extension Bars, AF500A, provides additional C13 outlets making the R5000 and extremely
flexible UPS for all environments.
Remotely Monitor UPSs on
the Network
The installed UPS Network Module enables network administrators to remotely monitor UPSs and reboot
network devices. It provides SNMP functionality, including power event alerts, network power diagnostics,
and remote UPS reboot and testing. Used in conjunction with HP Systems Insight Manager or other SNMP
capable Network Management Software, power-related problems on the network are quickly discovered
and remedied.
QuickSpecs
R5000 Uninterruptible Power System (UPS)
Standard Features
DA - 14109 North America — Version 5 — November 1, 2013
Page 3

Other manuals for HP R5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HP R5000 and is the answer not in the manual?

HP R5000 Specifications

General IconGeneral
BrandHP
ModelR5000
CategoryUPS
LanguageEnglish

Related product manuals