Replacing, moving, or adding hard drives 15
Replacing, moving, or adding hard drives
Drive LEDs
Dynamic Smart Array RAID controllers support drive LED illumination only on systems with backplane
support for drive LEDs.
In addition, Dynamic Smart Array RAID controllers support HPE Smart Carrier LED illumination. However,
LED functionality is provided only if the drives are authenticated through Smart Carrier.
The drive is being identified by a host application.
The drive carrier firmware is being updated or requires an
update.
3
Do not remove the drive. Removing the drive causes one or
more of the logical drives to fail.
Removing the drive does not cause a logical drive to fail.
The drive is a member of one or more logical drives.
The drive is rebuilding or is erasing.
amber/green
The drive is a member of one or more logical drives and predicts
the drive will fail.
The drive is not configured and predicts the drive will fail.
The drive is not configured by a RAID controller.
Recognizing drive failure
If any of the following occurs, the drive has failed:
• The drive status LED illuminates amber.
• When failed drives are located inside the server or storage system and the drive LEDs are not
visible, the Health LED on the front of the server or server blade illuminates. This LED also