FC port type value for imported HBAs
Brocade_topologyview.AntecedentFCPortType property value corresponding to the imported
HBA is shown as L_Port.
Migration Issue
Properties configured in the SMI Agent Configuration Tool do not migrate from DCFM 10.4.0 (Solaris)
to DCFM 10.4.0 (Windows) through the Copy Data and Settings screen when migrating from DCFM
10.4.0 (Solaris) to DCFM 10.4.0 (Windows) to Network Advisor 11.1.1 (Windows).
Documentation Updates
For the most recent Network Advisor documentation, visit the following HP website: http://
h18006.www1.hp.com/products/storageworks/dc_fabricmgr/index.html.
Under Support, select HP Support & Documents, and then select Manuals.
HP Network Advisor 11.1.0 fixes
Table 7 lists the defects that were closed for this release.
Table 7 HP Network Advisor 11.1.0 closed defects
SolutionClosed fixes summary
Fixed in HP Network Advisor 11.1.0.
Brocade Access Gateway (AG) switches running Fabric OS 5.3 were
not shown in DCFM and an inappropriate message was shown when
trying to rediscover the fabric.
Fixed in HP Network Advisor 11.1.0.
Master log reports port number and port index as one greater than
actual value.
Fixed in HP Network Advisor 11.1.0.
DCFM server runs out of memory when managing HP StorageWorks
SAN Director 2/128 or HP StorageWorks 4/256 SAN Director
switches for several weeks.
Fixed in HP Network Advisor 11.1.0.
Server backup fails to authenticate with Network drive after a server
reboot.
Fixed in HP Network Advisor 11.1.0.
The twelfth character of a LUN Serial Number (LSN) is getting dropped
on some paths in the Encryption Disk LUN View.
Fixed in HP Network Advisor 11.1.0.
Master Trunk ports in product tree and connections between AG and
a switch are not shown properly when F_Port trunking is enabled on
the AG setup.
Fixed in HP Network Advisor 11.1.0.
Remote VE_Port WWN is shown as missing and with a red icon under
end devices.
Fixed in HP Network Advisor 11.1.0.
Fault Management VFID is shown as Chassis for Switch name
change event in the master log.
Fixed in HP Network Advisor 11.1.0.
There are yellow dotted lines shown between the segmented switch
and the End Device in the re-discovered fabric.