6. Technical Specifications
6.1 HP T750 G4 NA/JP UPS, HP T1000 G4 NA/JP UPS, and HP T1500 G4 NA/JP UPS
HP T750 G4 NA/JP
UPS
HP T1000 G4 NA/JP
UPS
HP T1500 G4 NA/
JP UPS
Output Power @ 120V NA: 750 VA
525W
NA: 1000 VA
700W
NA: 1440 VA
1080W
Output Power @ 110V NA: 750 VA
525W
NA: 1000 VA
700W
NA: 1440 VA
1080W
Output Power @ 100V JPN: 750 VA
500W
JPN: 1000VA
680W
JPN: 1200 VA
980W
AC Input power
• Rated input voltage Single phase 100-120V
• Input voltage range 96 to 144V
• Input frequency
range
45 to 55 Hz (50 Hz system), 55 to 65 Hz (60 Hz system)
Output on battery power
• Voltage 100/110/120V (-10% to +5%)
(1)
• Frequency 50/60 Hz ±0.1 Hz
Battery (sealed lead acid, maintenance free)
• Standard
2 x 12V
7 Ah
2 x 12V
9 Ah
3 x 12V
9 Ah
Environment
• Operating tempera-
ture range
0 to 35°C/32 to 95°F
• Storage temperature
range
-15 to +40°C/5 to 104°F
• Relative humidity
0 to 90% (without condensation)
• Noise level
< 40 dBA in normal mode
(1) Adjustable to 100/110/120V, but must be set to the identical AC power source value.
Caution: To reduce the risk of re, connect only to a circuit provided with 20A maximum branch circuit overcurrent pro-
tection in accordance with the National Electric Code, ANSI/NFPA 70.
Filter
Transformer
AVR
Charger Inverter
Battery