lp-65 Rev. 002 Rel. 010 Date 10.11.19
11
3. After ensuring there are no leaks within the system, ush the
system to clear any soldering residue. Many soldering uxes contain
Zinc Chloride, which can corrode stainless steel.
Draw at least three times the volume of the water heater to properly
ush the system.
4. Initiate a call for hot water. Ensure each zone valve or circulator
operates only when its thermostat calls for heat. Purge each zone of
air to ensure proper operation.
5. Set the water heater to the desired temperature. Boiler high limit
should be set at least 20
o
F higher than the heater temperature.
Set the low limit of the boiler control at the minimum setting - this
will call the burner on
only to satisfy the tank
control.
A water heater
temperature setting of
120
o
F is recommended.
However, a lower
temperature setting
may be required to
comply with local
and state codes for
normal operation. The
dierential is xed 3
to 5
o
F. Installation
conditions may
require a higher or
lower temperature
setting. A mixing valve
in conjunction with
a high temperature
setting may be used
for high demand
applications (spas, hot
tubs, whirlpools).
6. When the system is
completely ushed,
purged of air, and the
temperature is set, turn
on the boiler. Observe
operation. Ensure the boiler shuts down after the indirect water
heater set point is satised.
1. Fill the water heater by opening the cold water shut-o valve.
Purge air from the system by opening a hot water outlet at a xture
in a kitchen or bathroom. When water ows freely from the outlet,
the system is purged.
Part 5 - Start-Up and Operation
When lling the water heater, open a hot water tap to release air
in the tank and piping to ensure proper water heater operation.
Failure to ensure the water heater is full before turning on the
system will result in damage to the water heater, and could result
in property damage. Such damages ARE NOT covered by warranty.
2. Check the system for leaks.
Fix any leaks before continuing the installation. Failure to do so
could result in property damage or personal injury.
Risk of scald injury increases as you increase water temperature.
10
12
13
6
1
11
2
5
8
3
7
4
9
ITEM #
REPLACEMENT
PART #
DESCRIPTION
1 6075P-002 HOT WATER OUTLET (SSC-35, SSC-50)
6075P-008 HOT WATER OUTLET (SSC-80, SSC-119)
2 6075P-001 COLD WATER DIP TUBE (SSC-35)
6075P-003 COLD WATER DIP TUBE (SSC-50)
6075P-009 COLD WATER DIP TUBE (SSC-80, SSC-119)
3 6075P-043 MAGNESIUM ANODE ROD
4 6060P-187 ELECTRICAL BOX COVER
5 6075P-006 #8 X 3/4 SELF TAPPING SCREWS (2)
6 6060P-965 INSULATION
7 6060P-634 PLASTIC PROTECTIVE COVER
8 6060P-632 5/16-18 HEX NUT - THERMODISC MOUNTING CLIP
9 6060P-630 GREEN GROUND WIRE W/RING
10 6060P-
633 THERMODISC MOUNTING CLIP
11 TD1010 THERMOSTAT CONTROL
12 2500P-0092 DRAIN VALVE
13 TP1000 3/4" RELIEF VALVE
LP-65-E
10/11/19
LP-65-E
10/11/19
Figure 15 - Replacement Parts