HPC - Upgrading Pro-C
The PRO-C model controller must be the NEWER PC- 400 version (blue buttons and solar sync dial
position) with a date code of MARCH 2014 or newer. This date code is written on the white sticker
inside the wiring compartment. Ensure you have a strong Wi-Fi signal. Wi-Fi connectivity can be tested
on the HPC panel itself (signal strength is shown when you select a wireless network). If you have any
issues connecting the controller to the router, please verify all Wi-Fi specifications here [1].
If you have the older model PC-300, the replacement controller is the HPC-400. If the station modules
in your older unit are black, they will work in the HPC-400 model controller.
PC-400 (Blue Buttons) Compatible PC-300 (Green Buttons) Not Compatible
NOTE: The compatible ribbon design in this panel should have two rows of pins. The single row of
pins would also indicate a panel that is not compatible.
Remove Pro-C Face Panel
1. Remove ribbon cable with power off.
2. Press down on the white hinge release button.
3. Remove face panel.
Install HPC-FP Face Panel
1. Press blue hinges together and attach a new HPC panel.
2. Reconnect ribbon cable
3. Close and turn the power on
STEPS
Copyright 2020 Hunter Industries. All Rights Reserved. 3

Other manuals for Hunter Hydrawise HPC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hunter Hydrawise HPC and is the answer not in the manual?

Hunter Hydrawise HPC Specifications

General IconGeneral
BrandHunter
ModelHydrawise HPC
CategoryController
LanguageEnglish

Related product manuals