14 Powermax30/30 XP/30 AIR Field Service Bulletin 805430
Power Cord Replacement
11 . Realign the front panel with the power supply.
12. Realign the rear panel with the power supply, making sure that the hole in the ground clip is aligned with the screw
holes in both the panel and the power supply.
13. Position the handle over the holes in the top of the cover, and position the ends of the handle underneath the edges
of the panels.
14. Reinstall the 2 screws that attach the cover and handle with a torque setting of 23.0 kg-cm (20 inch-pounds).
15. Reconnect the gas supply and power cord, and set the power switch to ON (I).