2-2 powermax600 Operator Manual
SPECIFICATIONS
0
Specifications, Power Supply
Rated Open Circuit Voltage (U
0
) 300 VDC
Rated Output Current (I
2
) 20 A – 40 A
Rated Output Voltage (U
2
) 140 VDC
Duty Cycle at 40°C 50 % (I
2
=40 A, U
2
=140 V)
(See data tag on power supply for 100 % (I
2
=28 A, U
2
=140 V
more information on duty cycle.)
Operating temperature -10° to +40°C (+14° to 104° F)
Apparent Input Power (S
1
) 230/400 V = 6.7 kVA
208-240/480 V = 9.5 kVA
Input Voltage (U
1
)/ Input Current (I
1
) at 230 V/17 A – 3-phase, 50/60 Hz CE
5.6 kW Output 400 V/9,7 A – 3-phase, 50/60 Hz CE
208-240 V/40-46 A – 1-phase, 50/60 Hz CSA/NRTL
480 V/12 A – 3-phase, 50/60 Hz CSA/NRTL
Gas Type Air Nitrogen
Gas Quality Clean, dry, oil-free 99.995 % pure
Gas Inlet Pressure and Flow See Section 3, Setup