7. When you want to separate the DC connectors, please use the specified tool to
do it. Please make sure the wedge side of the fingers face the MC4 plug
connector and push the tool down, as follows.
8. Please use sealing caps for tight sealing of unplugged DC input connectors.
If using H4 connector, the operating procedures are similar as that of MC4
connector.