10.2 Safety regulations
Protective devices
HPS-1500 / 2000 / 3000/3680 / 4000 / 5000/6000/6500;
HPS-1500D/ 2000D / 3000D/3680D / 4000D /
5000D/6000D/6500D
Inverter topology transformerless
DC isolator
PV iso / Grid monitoring ● / ●
DC reverse polarity
protection / AC short-
circuit current capability
● / ●
Residual current
monitoring(GFCI) function
Earth Fault Alarm cloud based, audible and visible(AU)
Protection class (according
to IEC 62103) / overvoltage
category (according to IEC
60664-1)
I / II(DC), III(AC)
Internal overvoltage
protection
Integrated
DC feed-in monitoring Integrated
Islanding protection Frequency shift, Integrated
EMC immunity EN61000-6-1, EN61000-6-2
EMC emission EN61000-6-3, EN61000-6-4
Utility interference EN61000-3-2, EN61000-3-3
●—Standard ○—Optional -—N/A