14
Ⅴ
ⅤⅤ
Ⅴ.
..
.
Usage, maintenance and charge of storage battery
Schematic diagram of charging method
Charging operation method: The truck is equipped with a charger. When the truck needs to be charged, first
open the cover of battery box to take out the charging plug from the side hole of the truck, then insert the charging
plug into the two –phase AC power. Finally, the charger starts charging after several seconds. (Battery charger and
its accessories are optional parts of the truck, please consult with the authorized representative to buy authentic
parts. This part shall fulfill the related safety requirements)
1
Initial charge
1.1
Initial charge shall be made for new battery, i.e. The first time charge. Clean up the surface of the battery
before the initial charge, and then check for damage to ensure reliable connection.
1.2 Open gas cap.
1.3 When the charging equipment is able to operate normally, pour the sulfuric acid electrolyte with
a density of 1.260±0.005 (25℃) and a temperature of lower than 30℃ into the batteries. The
electrolyte level should be 15-25mm higher than the protective board. In order to reduce the
Warning
Hydrogen is aggregated in the battery box when charging. For this reason, the
charging condition shall be good ventilated. In avoidance of explosion and fire
disaster, open flame is forbidden.