EasyManuals Logo
Home>IBC>Water Heater>30

IBC 30 User Manual

IBC 30
22 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #19 background imageLoading...
Page #19 background image
19
INSTALLATION AND OPERATION INSTRUCTIONS
IBC INDIRECT WATER HEATERS - ALL MODELS
Heat-Flo, Inc.
15 Megan Court, Uxbridge, MA 01569
Tel: 508-278-2400 Fax: 508-278-2466
www.heat-flo.com
MODEL
BOILER
OUTPUT
(BTU/HR)
140 F 115 F 140 F 115 F 140 F 115 F 140 F 115 F 140 F 115 F 140 F 115 F
50,000 94 119 67 92 103 128 67 92 121 146 67 92
60,000 107 138 80 111 116 147 80 111 134 165 80 111
80,000 134 174 107 147 143 183 107 147 161 201 107 147
100,000 160 212 133 185 169 220 133 184 187 238 133 184
120,000 171 227 144 200 190 250 154 214 214 275 160 221
140,000 171 227 144 200 190 250 154 214 227 293 173 239
160,000 171 227 144 200 190 250 154 214 227 293 173 239
MODEL
BOILER
OUTPUT
(BTU/HR)
140 F 115 F 140 F 115 F 140 F 115 F 140 F 115 F 140 F 115 F 140 F 115 F
50,000 121 146 67 92 139 164 67 92 170 195 67 92
60,000 134 165 80 111 152 183 80 111 183 214 80 111
80,000 161 201 107 147 179 219 107 147 210 250 107 147
100,000 187 238 133 184 205 256 133 184 236 287 133 184
120,000 208 268 154 214 232 293 160 221 263 324 160 221
140,000 208 268 154 214 239 303 167 231 289 360 186 257
160,000 208 268 154 214 239 303 167 231 289 360 186 257
MODEL
BOILER
OUTPUT
(BTU/HR)
140 F 115 F 140 F 115 F 140 F 115 F 140 F 115 F
50,000 139 164 67 92 170 195 67 92
60,000 152 183 80 111 183 214 80 111
80,000 179 219 107 147 210 250 107 147
100,000 205 256 133 184 236 287 133 184
120,000 232 293 160 221 263 324 160 221
140,000 258 330 186 258 289 361 186 258
160,000 285 368 213 296 316 398 213 295
180,000 312 405 240 333 343 435 240 332
200,000 339 442 267 370 370 473 267 370
220,000 343 473 271 401 396 509 293 406
240,000 362 473 290 401 412 531 309 428
250,000 362 473 290 401 412 531 309 428
(GAL/HR)
(GAL/HR)
(GAL/HR)
(GAL/HR)
RATING
RATING
RATING
RATING
(GAL/HR)
Boiler flow = 21 gpm
Boiler flow = 21 gpm
1st HOUR
CONTINUOUS
1st HOUR
CONTINUOUS
1st HOUR
CONTINUOUS
(GAL/HR)
(GAL/HR)
High Output Units - 80-HO and 115-HO - 21 gpm boiler flow
80-HO High Output
115-HO High Output
(GAL/HR)
(GAL/HR)
(GAL/HR)
RATING
RATING
RATING
RATING
RATING
RATING
1st HOUR
CONTINUOUS
60 LOW
80 and 80-C
115 and 115-C
Boiler flow = 14 gpm
Boiler flow = 14 gpm
Boiler flow = 14 gpm
1st HOUR
CONTINUOUS
RATING
RATING
(GAL/HR)
(GAL/HR)
(GAL/HR)
(GAL/HR)
(GAL/HR)
(GAL/HR)
RATING
RATING
RATING
RATING
Boiler flow = 14 gpm
Boiler flow = 14 gpm
Boiler flow = 14 gpm
1st HOUR
CONTINUOUS
1st HOUR
CONTINUOUS
1st HOUR
CONTINUOUS
180 deg. F Boiler Supply
30 and 40LOW
40
60
IBR Rating Condition
Table 6: Output ratings at 180°F boiler supply
Water Heater capacities and performance at 180°F supply water temperature from boiler