Table 85. Supported server to PDU power cords on POWER9 systems (continued)
Feature codes
(FC) Description
Voltage,
amperage, and
length
Power cord (left
end)
Power cord
(right end)
IBM part
number
EPAL Rong Feng/IEC
320 C20
200 – 240 V ac,
10 A, 2.8 m (9 ft)
RF-203P-M Plug Type 56 IEC
320 C20
01KU019
EPAM Rong Feng/IEC
320 C20
200 – 240 V ac,
10 A, 4.3 m (14
ft)
RF-203P-M Plug Type 56 IEC
320 C20
01KU020
Notes:
1. Feature code is specied as manufacturing select length when a rack is congured in the factory. The
default length is 4.3 m (14 ft). Additional lengths are 1 m (3.3 ft) PN 39M5506, 2 m (6.5 ft) PN 39M5508,
and 2.8 m (9 ft) PN 39M5509. FC EQ77 is quantity 150 of FC 6577. FC ENDQ is quantity 150 of FC END3.
2. India only.
3. Feature code is specied as manufacturing select length when a rack is congured in the factory. The
default length is 1 m (3.3 ft). Additional lengths are 2 m (6.5 ft) PN 01KV680, 2.8 m (9 ft) PN 01KV681, and
4.3 m (14 ft) PN 01KV682.
4. Feature code is specied as manufacturing select length when a rack is congured in the factory. The
default length is 1 m (3.3 ft). Additional lengths are 2 m (6.5 ft) PN 01PP688, 2.8 m (9 ft) PN 01PP689, and
4.3 m (14 ft) PN 001PP690.
5. Feature code is specied as manufacturing select length when a rack is congured in the factory. The
default length is 2 m (6.5 ft). Additional lengths are 2.8 m (9 ft) PN 01KU019, 4.3 m (14 ft) PN 01KU020.
Table 86. Supported power cords by countries
FC Supported countries
6460 American Samoa, Antigua and Barbuda, Aruba, Bahamas, Barbados, Belize, Bermuda,
Bolivia, Canada, Cayman Islands, Columbia, Costa Rica, Cuba, Dominican Republic,
Ecuador, El Salvador, Guam, Guatemala, Haiti, Honduras, Jamaica, Marshall Islands,
Mexico, Micronesia (Federal States of), Montserrat, Netherlands Antilles, Nicaragua,
Northern Mariana Islands, Palau, Panama, Peru, Philippines, Puerto Rico, San Marino,
Saudi Arabia, Thailand, Turks and Caicos Islands, United States, Venezuela
86 Power Systems: Site and hardware planning