2. Separate the inner and outer slides.
a. Open one of the slides until the lock engages.
b. Press the lock release lever (1 in Figure 4) and remove the inner rail from
the outer rail.
c. Repeat step 2a and step 2b for the other rail.
Note: For racks with flush-mount doors, such as the 9306 Netfinity
®
racks, do
not install the front brackets. Instead, use the rack-mount slides by
attaching the switch to the set of mounting holes, which are offset 3
inches into the rack.
3. Install the inner (smaller) slide on the switch chassis, as Figure 3 on page 11
shows.
Attention: If you use screws longer than 3/16 in., you can damage the switch.
a. Position the flat side of the inner rail along one side of the switch. Align the
holes in the rail with the threaded holes in the side of the switch chassis.
The chamfered end of the inner rail should face toward the rear of the
switch (away from the ports) as shown in Figure 5 on page 13.
b. Attach the inner rail by using three of the 8-32 x 3/16 in. zinc screws (6 in
Table 3 on page 11).
SJ000046
1
Figure 4. Separating the inner and outer rails
12 SAN24B-4 Installation, Service, and User Guide