v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The server does not turn off.
1. Turn off the server by pressing the power-control button for 5 seconds.
2. Restart the server.
3. If the server fails POST and the power-control button does not work, disconnect
the power cord for 20 seconds; then, reconnect the power cord and restart the
server.
Attention: In a dc power environment, only trained service personnel other
than IBM service technicians are authorized to connect or disconnect power to
the dc power supply. See the documentation that comes with each dc power
supply.
4. If the problem remains, suspect the system board.
The OVER SPEC LED on the
light path diagnostics panel is
lit, and the one of the power
channel LEDs on the system
board is lit.
See the power troubleshooting table in the Problem Determination and Service
Guide or call for service.
The server unexpectedly shuts
down, and the LEDs on the
operator information panel are
not lit.
See “Solving undetermined problems” in the Problem Determination and Service
Guide.
Serial port problems
v Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v See the parts listing in the Problem Determination and Service Guide to determine which components are
customer replaceable units (CRU) and which components are field replaceable units (FRU).
v If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom Action
The number of serial ports that
are identified by the operating
system is less than the number
of installed serial ports.
1. Make sure that:
v Each port is assigned a unique address in the Configuration/Setup Utility
program and none of the serial ports is disabled.
v The serial-port adapter (if one is present) is seated correctly.
2.
Reseat the serial port adapter, if one is present.
3. Replace the serial port adapter, if one is present.
72 IBM System x3650 Type 7979: Installation Guide

Table of Contents

Other manuals for IBM System x3650

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System x3650 and is the answer not in the manual?

IBM System x3650 Specifications

General IconGeneral
BrandIBM
ModelSystem x3650
CategoryServer
LanguageEnglish

Related product manuals