BASIC TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
No Power
The wiring not connected
correctly or bad wiring
Check the wiring or contact ICE Distributor
Bad brush motor Contact ICE Distributor
Carbon brushes worn out Contact ICE Distributor
Vacuum
motor does
not run
The wiring not connected
correctly or bad wiring
Check the wiring or contact ICE Distributor
Bad vacuum motor Contact ICE Distributor
Carbon brushes worn out Contact ICE Distributor
Little or no
solution ow
Bad ball valve Contact ICE Distributor
Bad solution valve Contact ICE Distributor
Ball valve position in need of
adjustment
When ball valve is in horizontal position,the
amount of solution ow is maximum.
Poor water
pick up
Squeegee clogged Clean debris off squeegee with a damp towel
Squeegee blades worn Install new squeegee blades
Squeegee not mounted
correctly
Conrm that the squeegee assembly is securely
fastened to the machine and not loose tting.
Vacuum hoses have a hole or
are loose
Check hose connections and make sure they
are rm. Replace hose if damaged.
Vacuum hose may be cloggedCheck hose for debris and remove any clog.
Drain hose stopper is loose Tighten drain plug.
Vacuum motor is loose
Tighten vac motor mounting screws. Do not
over tighten or damage will occur.
cover tank is loose Conrm the cover tank is securely in its place.
Recovery tank is full Drain recovery tank
Float shut off is clogged
Remove oat shut off from inside recovery tank
and remove any debris
short
runtime*
Low battery charge Fully recharge batteries
Defective batteries Replace batteries
Batteries need maintenance See BATTERY MAINTENANCE
Faulty battery charger Repair or replace battery charger
*