ICE iE410
5
OPERATOR
MACHINE MAINTENANCE
To keep the machine performing well for many years, please follow the following maintenance
procedures.
Always conrm that the machine is unplugged prior to performing any maintenance or
repairs!!!
DAILY MAINTENANCE
1. When cleaning operation is complete for the day, drain and rinse the recovery tank
thoroughly with clean water.
2. Remove remaining solution from solution tank.
3. Remove oat shut-off (ping pong ball in cage) from recovery tank and clean with water.
4. Remove and inspect spray jets. If necessary, clean jets in acetic acid solution.
Do not clean brass jets with a pointed object, as it will damage the jets.
5. Check brush assembly & remove any debris or carpet bers.
6. Check pick up head and remove any debris or carpet bers.
7. Check condition of the stainless steel pickup shoes on the pickup head. The shoes must
contact the oor for the whole length of the pickup head. Replace as necessary.
8. Clean machine with a nonabrasive cleaner.
9. Inspect power cable for any damage. Replace if necessary.
MONTHLY MAINTENANCE
1. Flush pump & plumbing with an acetic acid solution to dissolve any chemical buildup.
Mixing Instructions:
a) Premix 16 oz. or an acetic acid solution with 2 gallons of water and pour into solution tank.
b) Turn vacuum / pump switch on
c) Put machine head over oor drain and operate machine for 50 seconds.
d) Shut machine down and allow remaining solution to sit in machine overnight.
e) The following day, spray out remaining solution and ush system again with 3 gallons of
clean water.
2) Inspect machine for water leaks.
3) Lubricate wheels with a water resistance lubricant.
MACHINE STORAGE
1. Prior to storing the machine, ensure the solution and recovery tanks are clean and empty
of any solution.
2. Store machine in upright position in a dry area, with the brush head off the oor.
3. Remove recovery tank clear lid to allow for air circulation.
If you are storing the machine in an area which can freeze, be sure both tanks and
the solution plumbing are empty of all water and dry!

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ice iE410 and is the answer not in the manual?

Ice iE410 Specifications

General IconGeneral
BrandIce
ModeliE410
CategoryFloor Machine
LanguageEnglish