6
ADJUSTING THE LOW VOLTAGE CUT-OFF:
BATTERY START PROTECTION:
ICECO Fridge come with three different settings for voltage cut-offs:
1. The fridges comes withs a 5-second start-up delay for the fan and a 20-second start-up delay for the
compressor.
This is used to not overload the battery of the vehicle when it is frist starting.
2. During the 20-second delay,the user can still adjust settings.
TROUBLESHOOTING:
Code Description Action
E1
Battery Voltage is low. Check battery voltage and adjust Low Voltage
Cutt-Off as required.
E2
Fan failure / Frequent start-stop. Contact point of sale to arrange further action.
E3
Compressor startup problems.
Check air vents are clear.
Move fridge to cooler location (ambient temperature
may be too high).
E4
Compressor’s running speed fails
to reach the requirements.
E5
The model is overloading.
E6
NTC failure(open circuit or short
circuit)