5 - 5
5-3 ADJUSTMENT MODE ADJUSTMENTS
• The following adjustments must be performed at “ADJUSTMENT MODE”.
• The following adjustments can be adjustned automatically. The detail shows “AUTOMATICALLY ADJUSTMENT”
(at page 5-8).
BAR
ANTENNA
VHF
SENSITIVITY
UHF
SENSITIVITY
ADJUSTMENT
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT LOCATION UNIT ADJUST
1
2
3
4
1
2
3
4
1
2
3
4
• Displayed frequency :
(trL ch) 0.495 MHz
• Connect an SSG to the antenna
connector and set as:
Level : 40 mV
* (–15 dBm)
Modulation : OFF
• Receiving
• Displayed frequency :
(trH ch) 1.620 MHz
• Set the SSG as
Level : 50 mV* (–13 dBm)
• Receiving
• Displayed frequency :
(trL ch) 118.100 MHz
• Connect an SSG to the antenna
connector and set as:
Level : 1 µV* (–107dBm)
Modulation : OFF
• Receiving
• Displayed frequency :
(trH ch) 174.900 MHz
• Receiving
• Displayed frequency :
(trL ch) 330.100 MHz
• Connect an SSG to the antenna
connector and set as:
Level : 1 µV
* (–107dBm)
Modulation : OFF
• Receiving
• Displayed frequency :
(trH ch) 469.900 MHz
• Receiving
RF
RF
RF
RF
RF
RF
Connect DC volt-
meter to the check
point SEN.
Connect DC volt-
meter to the check
point SEN.
Connect the digital
multi-meter to the
check point SEN.
Connect DC volt-
meter to the check
point SEN.
Connect the digital
multi-meter to the
check point SEN.
Connect DC volt-
meter to the check
point SEN.
Maximum voltage
Maximum voltage
Maximum voltage
Maximum voltage
Maximum voltage
Maximum voltage
LOGIC
LOGIC
LOGIC
LOGIC
LOGIC
LOGIC
[DIAL]
[DIAL]
[DIAL]
[DIAL]
[DIAL]
[DIAL]
*This output level of the standard signal generator (SSG) is indicated as SSG’s open circuit.
• Push and hold the [FUNC] key, and then push the [V/M] key.
• Push and hold the [FUNC] key, and then push the [V/M] key.
• Push and hold the [FUNC] key, and then push the [V/M] key.
• Push and hold the [FUNC] key, and then push the [V/M] key.
• Push and hold the [FUNC] key, and then push the [V/M] key.
• Push and hold the [FUNC] key, and then push the [V/M] key.