5
To shut Down the Boiler
1. For short periods
Set the external controls to OFF. Wait 2 minutes and then
isolate the mains supply to the boiler.
2. For longer periods
Set the external controls to OFF. Wait 2 minutes and then
isolate the mains supply to the boiler. For longer periods the
entire system should be drained, including the domestic hot
water supply.
To Relight the Boiler
Rell the system if it has been drained, taking care to ensure no
air is in the boiler or system.
Repeat the procedure detailed in 'To light the boiler'.
Frost Protection
The boiler has built into its control system the facility to
protect the boiler only against freezing.
Note.
This may not protect remote parts of the system, in which case a
separate frost protection should be tted.
Boiler Overheat
Boiler overheating is detected by electrical sensors connected to
the boiler control module. If the boiler overheats it will shut down
and the display will show Overheat Lockout. Press the 'reset'
button then turn the knob so that the Module is highlighted and
press reset again and the boiler will relight. If the fault recurs turn
off the boiler and consult a Gas Safe Registered Engineer or in IE
a competent person.
Condensate Drain
The condensate drain must not be modied or blocked.
Blockage of the condensate drain, caused by debris or freezing,
can cause automatic shutdown of the boiler or leakage from the
condensate trap mounted on the bottom of the boiler.
If freezing is suspected and the pipe run is accessible an attempt
may be made to free the obstruction by pouring hot water over
the exposed pipe and clearing any blockage from the end of the
pipe. If this fails to remedy the problem the assistance of a Gas
Safe Registered Engineer or in IE a competent person should be
sought.
Escape of Gas
Should a gas leak or fault be suspected contact your local gas
supplier without delay.
Do NOT search for gas leaks with a naked ame.
Cleaning
For normal cleaning simply dust with a dry cloth.
To remove stubborn marks and stains use a damp cloth and mild
detergent.
DO NOT use abrasive cleaning materials.
- Users

Other manuals for IDEAL EVOMOD 250

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL EVOMOD 250 and is the answer not in the manual?

IDEAL EVOMOD 250 Specifications

General IconGeneral
BrandIDEAL
ModelEVOMOD 250
CategoryBoiler
LanguageEnglish

Related product manuals