EasyManuals Logo
Home>IDEAL>Boiler>isar HE24

IDEAL isar HE24 User Manual

IDEAL isar HE24
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
41
SERVICING
isar - Installation and Servicing
2
3
1
4
Ecl 6073
52
FAN AND VENTURI ASSEMBLY REMOVAL AND CLEANING
53
BURNER REMOVAL AND CLEANING
1. Remove the 6 screws securing the
burner (the 3 screws at the rear are
extended to ease access).
2. Lift off the burner from the combustion
chamber.
IMPORTANT
The burner head is a ceramic plaque
construction. Care must be taken to
ensure that the burner is not placed
down upon its face as this may cause
damage to the ceramic.
3. Brush off any deposits that may be on
the ceramic with a SOFT brush.
4. Inspect the sealing gasket around the
burner and combustion chamber
insulation for any signs of damage.
Replace as necessary.
Note.
Take care not to disturb the ionisation
probes at the front and rear of the
combustion chamber.
1. Disconnect the electrical leads from the
fan.
2. Undo the gas pipe union connection to the
injector housing.
3. Undo the screw on the fan mounting
bracket.
4. Lift off fan and venturi assembly.
5. Inspect the injector for blockage or
damage.
nm7400
Ionisation
Probes
1
2
4
SERVICING