Ideal Logic Combi 24 30 35
Gas supply 2H - G20 - 20mbar
Gas Supply Connection 15mm copper compression
Injector Size (mm) 4.15 4.65 4.9
Inlet Connection Domestic Hot Water 15mm copper compression
Outlet Connection Domestic Hot Water 15mm copper compression
Flow Connection Central Heating 22mm copper compression
Return Connection Central Heating 22mm copper compression
Flue Terminal Diameter mm (in) 100 (4)
Average Flue Temp-Mass Flow Rate (DHW) 63
o
C - 11g/s 68
o
C - 13g/s 73
o
C - 15g/s
Maximum Working Pressure (Sealed Systems) bar (lb/in
2
) 2.5 (36.3)
Maximum Domestic Hot Water Inlet Pressure bar (lb/in
2
) (kPa) 10.0 (145) (1000)
Minimum Domestic Hot Water Inlet Pressure* bar (lb/in
2
) (kPa) 0.8 (11.6) (80) 1.3 (18.9) (130) 1.3 (18.9)** (130)
Electrical Supply 230 V ~ 50 Hz.
Power Consumption W 146 152 177
Fuse Rating External : 3A Internal : T4H HRC L250 V
Water content Central Heating litre (gal) 1.2 (0.26)
Domestic Hot Water litre (gal) 0.5 (0.11)
Packaged Weight kg (lb) 36.3 (80.3) 36.5 (80.6) 36.5 (80.6)
Maximum Installation Weight kg (lb) 31.8 (70.3) 32 (70.8) 32 (70.8)
Boiler Casing Size Height mm (in) 700 (27.5)
Width mm (in) 395 (15.5)
Depth mm (in) 278 (11)
Table 1 - General Data
Note. Gas consumption is calculated using a
caloric value of 38.7 MJ/m
3
(1038 Btu/ft
3
) gross
or 34.9 MJ/m
3
(935 Btu/ft
3
) nett
To obtain the gas consumption at a different
caloric value:
a. For l/s - divide the gross heat input
(kW) by the gross C.V. of the gas (MJ/m
3
)
b. For ft
3
/h - divide the gross heat input (Btu/h)
by the gross C.V. of the gas (Btu/ft
3
)
c. For m
3
/h - multiply l/s by 3.6
Key to symbols
GB = United Kingdom IE = Ireland (Countries of destination)
PMS = Maximum operating pressure of water
C
13
C
33
C
53
= A room sealed appliance designed for connection via ducts to a
horizontal or vertical terminal, which admits fresh air to the burner
and discharges the products of combustion to the outside through
orices which, in this case, are concentric. The fan is up stream of
the combustion chamber.
I
2H
= An appliance designed for use on 2nd Family gas, Group H only.
* The value is used in the UK Government’s Standard Assessment Procedure (SAP) for energy rating of dwellings. The test data from
which it has been calculated have been certied by a notied body.
*Required for maximum ow rate. Boiler operates down to 2 l/min DHW delivery
** In areas of low water pressure the DHW restrictor can be removed
Maximum DHW Input : 24 30 35
Nett CV kW 24.3 30.4 35.4
(Btu/h) (82,900) (103,600) (120,900)
Gross CV kW 27.0 33.7 39.3
(Btu/h) (92,000) (115,000) (134,200)
Gas Consumption m
3
/h 2.512 3.135 3.657
(ft
3
/h) (89) (111) (129)
Maximum kW 24.2 30.3 35.3
DHW Output (Btu/h) (82,600) (103,300) (120,500)
DHW Flow Rate l/min 9.9 12.4 14.5
at 35°C temp. rise. (gpm) (2.2) (2.8) (3.2)
DHW Specic Rate l/min 11.5 14.5 16.9
(gpm) (2.5) (3.2) (3.7)
Boiler Input : Max. Min.
24 30 35
Boiler Input ‘Q’ Nett CV kW 24.3 4.9 6.1 7.1
(Btu/h) (82,900) (16,600 (20,700 (24,100)
Gross CV kW 27.0 5.4 6.7 7.9
(Btu/h) (92,000) (18,400) (23,000) (26,900)
Gas Consumption m
3
/h 2.512 0.500 0.627 0.734
(ft
3
/h) (89) (17.8) (22) (25.9)
Boiler Output :
Non Condensing kW 24.2 4.8 6.1 7.1
70
o
C Mean Water temp. (Btu/h) (82,600) (16,500) (20,700) (24,100)
Condensing kW 25.6 5.1 6.4 7.5
40
o
C Mean Water temp. (Btu/h) (87,400) (17,500) (21,800) (25,500)
Seasonal efciency* SEDBUK 2005 91% 91.1% 91%
Seasonal efciency* SEDBUK 2009 89% 89% 88.9%
NOx Classication CLASS 5
Table 2 - Performance Data - Central Heating
Table 3 - Performance Data - Domestic Hot Water