DOC No: PN 86880 REV A
11
LOCATION
Pump head cannot support the weight of the motor. Ensure
the motor is adequately supported by the foundation and/or
mounting bracket.
The foundation must be capable of supporting the combined weight
of the pump and motor and provide a rigid support.
The product should be located with the inlet below or even with the liquid level of
the uid supply. The product can be mounted in any position. Ensure that there is
adequate space for operation, inspection and maintenance.
BULKHEAD MOUNTING
(DEELE MODEL)
If mounting the pump/EagleDrive assembly through a bulkhead, insert the
bulkhead o-ring (ITEM 1) into the groove in the face of the housing (ITEM 3).
Position the adaptor ange (ITEM 2) through the bulkhead hole so that it does
not interfere with the sealing of the bulkhead hole. Secure the pump/EagleDrive
assembly using four screws, nuts, and washers as needed. Tighten screws evenly
and in an alternating pattern.
ITEM 1: o-ring 2-040 described below is necessary to ensure
bulkhead is sealed.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Idex MICROPUMP EAGLEDRIVE EMSN Series and is the answer not in the manual?

Idex MICROPUMP EAGLEDRIVE EMSN Series Specifications

General IconGeneral
BrandIdex
ModelMICROPUMP EAGLEDRIVE EMSN Series
CategoryEngine
LanguageEnglish

Related product manuals