DOC No: PN 86880 REV A
12
REQUIRED EAGLEDRIVE
ELECTRICAL CONNECTIONS
Electrical installation must be carried out by qualied personnel
who are conversant with local electricity installation regulations.
Before starting any electrical installation work ensure that the main
electrical supply is adequately isolated.
Ensure that the pump motor is earthed. The pump may be electrically
isolated from the motor depending on the mounting conguration.
Some installations may need an earthing connection on the pump head.
Pumping ammable uids without a proper earthing connection may
cause spontaneous ignition.
Ensure that all electrical connections use a common earth ground to
avoid hazardous ground loops.
MAIN Power In
24 +/- 12Vdc (nominal), voltage ripple must be maintained below 5% peak-to-peak,
from SELV Class2 or Limited Power Source, Micropump always recommends
external overcurrent protection (MODEL MS ~2A, MODEL EL ~3A), internal
hardware-current-limit decreases motor speed to hold at current limit until rotation
stops (stall), in locked-rotor condition maximum stall current is ~1.2A.
If locked rotor operation occurs at full load current in greater
than 70°C ambient temperature conditions can result in winding
temperatures greater than UL 1004 limits. To reduce risk of
exceeding winding temperature limits Micropump recommends
always monitoring the tachometer signal and commanding stop
if the pump shows a locked rotor condition lasting more than
one minute.
Ensure that the voltage of the supply is correct for the motor being
connected, and that the source is SELV Class 2 or a Limited Power
Source. Ensure that the power supply voltage ripple is maintained
below 5% peak to peak.
Ensure that all associated equipment has a form of overcurrent
protection. If a fuse is used see table below for recommendations.
EAGLEDRIVE MODEL RECOMMENDED FUSE
DEMSE LITTLEFUSE 0313002 HXP
DEELE LITTLEFUSE 0313003 HXP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Idex MICROPUMP EAGLEDRIVE EMSN Series and is the answer not in the manual?

Idex MICROPUMP EAGLEDRIVE EMSN Series Specifications

General IconGeneral
BrandIdex
ModelMICROPUMP EAGLEDRIVE EMSN Series
CategoryEngine
LanguageEnglish

Related product manuals