11
Installation
In order to prevent damage of the
product, please use the voltage
stabilizer.
After unpacking the hob, make sure that
it has not been damaged during transport.
In the event of problems, contact the
dealer or your nearest After-sales Service.
Technical information for the installer
- Before installation, make sure that:
The local gas delivery conditions
(nature and pressure) are compatible
with the settings of the hob (see the
rating plate and injector table)
- Combustion products are discharged
outdoors through specific hoods or wall
and/or window mounted electrical fans.
- The outer surface of the furniture or
appliances adjacent to the hob are heat
resistant according to local regulation
Gas connection
This operation must be performed
by a qualified technician.
The gas supply system must comply
with local regulations to the relevant
gas standard.
- “Reference to Local Regulations”. If no
information concerning your Country is
given, please ask details to a qualified
technician.
- The connection of the hob to the gas
pipe network or gas cylinder must be
made by means of a rigid copper or
steel pipe with fittings complying with
local regulations, or by means of a
continuous-surface stainless steel
hose complying with local regulations.
The maximum length of the hose is 2
linear metres.
IMPORTANT: if a
stainless steel hose is
used, it must be installed
so as not to touch any
mobile part of the
furniture.
It must pass through an
area where there are no
obstructions and where it is
possible to inspect it on all
its length.
- After connection to the gas
supply, check for leaks with
soapy water. Light up the
burners and turn the knobs
from max position to sim
position
to check flame
stability
Adjustment to different type of gas
WARNING
- This operation must be performed
by a qualified technician.
If the appliance is intended to operate
with a different gas from the gas type
stated on the rating plate and
information label on the top of the
hob, change the injectors.
Remove the information label and keep
it with the instructions booklet.
appliance is not connected t
fume exhaust device. It shall be
installed in accordance with current
installation regulations. Particular
attention shall be given to the relevant
requirement regarding ventilation