8 Intel® RAID Expander Card RES2SV240 Hardware User’s Guide
Figure 3. Installing the Expander Card onto a Customized Chassis Wall
6. Connect the SAS/SATA cables from the backplane (or hard drives) to the e
xpander
card, and from the expander card to a RAID module or RAID controller (see
Figure 4, which takes 6-drive and 4-drive non-expander backplanes in Intel's
pedestal chassis as an example for cabling). For information regarding connecting
the recommended Right-angle
end or Vertical end of the SAS/SATA cable to the
SAS connectors of the controller, see your server/workstation board or chassis
documentation. Make sure the cables are properly connected to the controller.
Note: S
ystem throughput problems can occur if non-standard SAS cables are used.
To
minimize the potential for problems:
Use cables no longer than ten meters for SAS
and one meter for SATA. It is
better to use the shortest possible cables. The cable length should be reduced
by about one foot (.33 meters) if using a backplane.
You may connect one device per SATA/SAS cable either as a device or as an
ex
pander.
Route SAS cables carefully.
Use only “straight” SAS cables, not “cross-over” SAS cables.
AF003495

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Intel RES2SV240 and is the answer not in the manual?

Intel RES2SV240 Specifications

General IconGeneral
BrandIntel
ModelRES2SV240
CategoryComputer Hardware
LanguageEnglish

Related product manuals