TROUBLESHOOTING GUIDE
• Themotorisnotpluggedin.
• Switchisnotturnon.
• TheGFCIcircuitbreakeristripped.
• Motortoohotandoverload
protection is shut off.
• ImpropersanitizerorpHlevels.
• Filtercartridgeisdirty.
• Damagedcartridge.
• Excessivelydirtypool.
• Thestrainerscreenisrestrictingthe
water flow.
• Cloggedinletordischarge.
• Anairleakontheintakeline.
• Scaleorbuilduponcartridge.
• Excessivelydirtypool.
• Dirtyfiltercartridge.
• Thevacuumreleasevalveonthe
plunger valve is activated.
• Thevacuumreleasevalveonthe
plunger valve is leaking.
• Lowwaterlevel.
• Strainerscreenpluggedup.
• Anairleakontheintakehose.
• Anairlockinsidethecartridge
chamber and motor chamber.
• Servicelighton.
• O-ringmissing.
• Coverisnottight.
• Filtercartridgeisdirty.
•Hosenutsarenotwell-fitted.
• There’sairtrappedinthepump
housing and inlet hose.
• Theinletandoutlethoses
connection are reversed.
PROBLEM CAUSE SOLUTION
FILTER MOTOR FAILS
TO START
FILTERDOESN’T
CLEANPOOL
FILTERDOESN'T
PUMP WATER OR
FLOW IS VERY SLOW
PUMPDOESN'T
WORK
TOPCOVERLEAKING
HOSELEAKING
AIR LOCK
• Filtercordmustbepluggedintoa3wireoutlet
thatisprotectedbyaClassAGroundFault
Circuit Interrupter, or RCD.
• Resetcircuitbreaker.Ifcircuitbreakertrips
repeatedly, your electrical system may have a
defect. Turn off circuit breaker and call an
electrician to correct the problem.
• Letmotorcooldown.
•
Adjust the sanitizer and pH level. Consult your
local swimming pool supply stores.
• Cleanorreplacecartridge.
• Checkthecartridgeforholes.Replaceif
damaged.
• Operatethefilterforlongerperiods.
• Cleanthestrainerscreenattheinlet.
• Clearanyobstructionsintheintakehoseby
discharging it inside pool wall.
• Tightenhosenuts,checkhosesfordamage,
check pool water level.
• Replacecartridge.
• Cleancartridgemoreoften.
• Cleaninsidetheplungervalve.
• Pullvalvehandletofulluprightposition.
• Turnoffpump,clearanydebrisorobstructionintheoutlet,
remove all air from the filter pump and turn pump on again.
• Turnoffpump,ifwaterleakingfromthevacuumrelease
valve, then release valve needs to be replaced. Contact
Intex Service Center immediately to order replacement.
You may cover release valve with the cap temporarily if
you ensure that the strainer cover / strainer grid is installed
and you Do Not run the pump while pool is occupied.
• Fillpooltocorrectwaterlevel.
• Cleanstrainerscreensatpoolinlet.
• Tightenhosenuts,checkhosefordamage.
• Clearanysticksorleavesintheintakehose.
• Turnandpullvalvehandletofullupright
position.
• Unscrewtwoairreleasevalveonthechamber
to fullfill water.
• ContactIntexServiceCenter.
• Removecover&checkforO-ring.
• Tightencover(Manually).
• Replaceorcleancartridge.
•Tightenorreinstallhosenut.
• Openairreleasevalves,liftandlowertheinlet
hose until water starts to flow
out of the valve, then close it.
• Thelowerpositionofpooloutletconnectsto
filter pump water inlet. The upper position of
pool inlet connects to filter pump water outlet.