TTRROOUUBBLLEESSHHOOOOTTIINNGG GGUUIIDDEE
TROUBLESHOOTING GUIDE (continued)
I
NSUFFICIENT
CHLORINE
INSUFFICIENT
COPPER ION
LEVEL
POOL IS STAINED
WHITE FLAKES IN
THE WATER
NO LED DISPLAY
GREEN HAIR
• Insufficient operating hours of
the Saltwater System.
• The salt level in the pool water
is less than 2000ppm. This is
insufficient.
•
Chlorine loss due to intense
sunlight exposure.
• The bather load has increased.
• Clogged or dirty electrolytic cell.
• Insufficient operating hours.
• The PH is too high.
• The bather load has increased.
• Clogged or dirty copper
electrode.
• Copper electrode defective.
• High copper ion concentration.
• Excessive calcium hardness is
present in pool water.
• No power supply.
• RCD/GFCI has not reseted.
• A power fuse has blown.
• LED failure.
• Incorrect switching, press two
buttons ( and ) together.
• High copper ion concentration.
•
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
•
Check the salt level with the Test Kit. Adjust
as needed. See “Salt & Pool Water
Volumes”.
•
U
se a pool cover when the pool is not in
use and/or when the unit is operating.
•
Increase the daily Saltwater System
operating time. See “Operating Instructions”.
•
Remove the cell for inspection, clean it if
necessary. See “Maintenance”.
• Increase operating time per day. See
“Operating Instructions”.
• Use PH decrease chemical to adjust,
contact your local pool chemical store.
• Increase the operating time per day.
See “Operating Instructions”.
• Remove the cell for inspection, clean it
if necessary. See “Maintenance”.
• Contact Intex Service Center.
• Drain about 20% of the pool water and
add fresh water to decrease the copper
ion concentration below 0.2ppm.
• Add aluminum sulfate: 1000 liters
water need around 2g (1000 gals need
0.27 ounce) or aluminum potassium
sulfate: 1000 liters water need around
3g (1000 gals need 0.4 ounce) to pool.
• Use a lemon based cleaning product
(preferably containing citric acid). Don’t
scrub with aggressive cleaning
products because this might etch the
underlying surface.
• Drain about 20 to 25% of the pool
water and add fresh water to decrease
the calcium hardness. Inspect the
electrolytic cell for scale buildup. Clean
the electrolytic cell if necessary.
•
Plug the cell cord firmly into the cell
housing receptacle.
•
Reset the RCD/GFCI.
•
Contact Intex Service Center.
•
Contact Intex Service Center.
•
Shut down and turn on the power again,
re-set the time. See “Operating Instructions”.
• Drain about 20% of the pool water and
add fresh water to decrease the copper
ion concentration below 0.2ppm.
• Add aluminum sulfate: 1000 liters
water need around 2g (1000 gals need
0.27 ounce) or aluminum potassium
sulfate: 1000 liters water need around
3g (1000 gals need 0.4 ounce) to pool.
• Use ‘Ultra-Swim’ shampoo, or shampoo
containing chelating agents.
P
ROBLEM CAUSE SOLUTION