LED CODE CHART
E90
Nowaterow
• Turn off and unplug the control unit.
• Ensure the outlet cover grid is clean and free
from obstructions.
• Clean or replace the cartridge, see
Maintenance and Storage section.
• Ensure the in/outlet connections on the spa tub
andlterpumparenotblocked.
• Keep the spa water properly sanitized to
ensureacleananduncloggedltercartridge.
• If problem persists, contact Intex Service
Center.
E94
Water temperature too low
• If the ambient temperature is below 4°C (39°F),
we recommend not to use the spa.
• Turn off and unplug the control unit, add some
warm water to raise the spa water temperature
above 5°C (41°F), then press the button to
heat up the water to the desired temperature.
• If problem persists, contact Intex Service
center.
E95
Water temperature too high
• Turn off and unplug the control unit. When the
water has cooled down, plug the RCD and
restart all over again.
• Turntheheateroff,thenpressthelterand
bubble buttons to lower the water temperature.
• If problem persists, contact Intex Service
Center.
E96
System Error
• Turn off and unplug the control unit. Plug the
RCD and restart all over again.
• If problem persists, contact Intex Service
Center.
E97
Dry-reProtection • Contact Intex Service Center.
E99
Water temperature sensor broken • Contact Intex Service Center.
END
After 72 hours of continuous
heating operation, the pump will
hibernate automatically. The rapid
heatingandwaterltration
functions are disabled.
• Press the button to re-active the
lterpump.
LED Reading CAUSE SOLUTION