TROUBLESHOOTING
NO DISPLAY/SPA
CONTROL UNIT DOES
NOT WORK
HOUSEHOLD CIRCUIT
BREAKER TRIPPED
NOT HEATING
PROPERLY
BUBBLE AIR BLOWER
DOES NOT WORK
FILTRATION PUMP
NOT WORKING
WATER NOT CLEAN
PUMP CONNECTORS
ARE NOT LEVEL WITH
THE SPA CONNECTORS
TUB HAS A STRANGE
SHAPE
TUB LOSES AIR
PRESSURE
LEAKING BETWEEN SPA
TUB CONNECTORS AND
CONTROL UNIT
CONNECTORS
SPA IS TOO NOISY IN
FILTRATION MODE ONLY
Spa is unplugged or off.
Control panel cable plug loose.
Power failure.
RCD tripped.
RCD broken.
Circuit breaker under rated.
Overloaded circuit breaker.
An electrical fault in the line.
Temperature set too low.
• Dirtyltercartridge.
Water temperature decreasing during
heater STANDBY mode.
Heating element failed.
Air blower pump is too hot.
• Dirtyltercartridge.
Filtration inlet and/or outlet clogged.
Filter pump motor failed.
Cartridge assembly not properly attached.
• Insufcientlteringtime.
• Dirtyltercartridge.
Improper water maintenance.
Filtration inlet and outlet clogged.
One characteristic of PVC is that
it changes shape, which is normal.
Expanded internal air pressure by
strong sunshine.
Air valve cap loose.
Air valve base loose.
Hole, cut or split on spa tub.
Spa control base inlet/outlet connections
not securely tight.
Spa control base inlet/outlet o-ring
missing/dirty.
Control base components not securely
attached.
• Controlbasegroundnotlevelandrm.
• Spaltermotorfailed.
Ensure the spa is plugged and switched on.
• Ensurethecontrolpanelcableplugisrmly
attached to the control base receptacle.
Check power source.
Reset the RCD.
Contact Intex Service Center.
Ensure correct circuit breaker rating.
Provide a dedicated circuit breaker feeding the
spa electrical outlet only.
Contact a qualify electrician to correct the
electrical fault.
Increase the temperature and attach the spa
cover.
• Cleanorreplacetheltercartridgeintime.
•IfheaterisinSTANDBYmode,presstheamebutton
twice to heat up the water to the set temperature.
Contact Intex Service Center.
Turn off and unplug the spa. Let it cool down and
restart all over again.
If problem persists contact Intex Service Center.
• Cleanorreplacetheltercartridgeintime.
• Checkandcleanltrationinletandoutletregularly.
Contact Intex Service Center.
Ensure the cartridge assembly is properly attached.
• Increaseltrationtime.
• Cleanorreplacetheltercartridgeintime.
Keep the spa water properly sanitized. Refer to the
chemical manufacturer’s instructions.
• Checkandcleanltrationinletandoutletregularly.
Elevate the pump with wood or another type of
insulated material to bring the pump’s connectors
level with the spa’s connectors.
Do not expose the spa to direct sunlight for extended period of time.
Check the air pressure and release air if necessary.
During very hot weather, you must check to see whether it is
necessary to release some air. This is to avoid any possible
damage to the tub.
Ensure air valve cap is securely closed.
Fill up the spa tub with air then make sure the air valve
base is tighten, see “Spa Tub Air Valve Fastening” section.
Put liquid soap and water in a squirt bottle and spray on
seams.Ifthereisaleakitwillbubble.Afteryoundtheleak,
clean and dry the leaking area, then apply the repair patch
that comes with your spa.
Tighten inlet and outlet connections.
Coat the o-ring with petroleum jelly for water proof.
Remove grid from inside spa with a screwdriver,
ensure inlet/outlet O-ring is in place, clean and not
damaged.
Ensure control panel, back cover and all inlet/outlet
are securely connected.
• Ensuregroundislevel,rmandsmooth.
• Replacethefailedltermotorwithanewone.
PROBLEM CAUSE SOLUTION