Detailed Function Description
93
This parameter determines whether the running step and output frequency of simple
PLC should be saved. If PA.01 is set to be 2, running step and output frequency will be
saved when inverter stops, but will not be saved when inverter is power off
Function
Code
Name Description Setting Range
Factory
Setting
PA.02 Multi-step speed 0 -100.0~100.0% -100.0~100.0 0.0%
PA.03 0
th
Step running time 0.0~6553.5s(h) 0.0~6553.5 0.0s
PA.04 Multi-step speed 1 -100.0~100.0% -100.0~100.0 0.0%
PA.05 1
st
Step running time 0.0~6553.5s(h) 0.0~6553.5 0.0s
PA.06 Multi-step speed 2 -100.0~100.0% -100.0~100.0 0.0%
PA.07 2
nd
Step running time 0.0~6553.5s(h) 0.0~6553.5 0.0s
PA.08 Multi-step speed 3 -100.0~100.0% -100.0~100.0 0.0%
PA.09 3
rd
Step running time 0.0~6553.5s(h) 0.0~6553.5 0.0s
PA.10 Multi-step speed 4 -100.0~100.0% -100.0~100.0 0.0%
PA.11 4
th
Step running time 0.0~6553.5s(h) 0.0~6553.5 0.0s
PA.12 Multi-step speed 5 -100.0~100.0% -100.0~100.0 0.0%
PA.13 5
th
Step running time 0.0~6553.5s(h) 0.0~6553.5 0.0s
PA.14 Multi-step speed 6 -100.0~100.0% -100.0~100.0 0.0%
PA.15 6
th
Step running time 0.0~6553.5s(h) 0.0~6553.5 0.0s
PA.16 Multi-step speed 7 -100.0~100.0% -100.0~100.0 0.0%
PA.17 7
th
Step running time 0.0~6553.5s(h) 0.0~6553.5 0.0s
PA.18 Multi-step speed 8 -100.0~100.0% -100.0~100.0 0.0%
PA.19 8
th
Step running time 0.0~6553.5s(h) 0.0~6553.5 0.0s
PA.20 Multi-step speed 9 -100.0~100.0% -100.0~100.0 0.0%
PA.21 9
th
Step running time 0.0~6553.5s(h) 0.0~6553.5 0.0s
PA.22 Multi-step speed 10 -100.0~100.0% -100.0~100.0 0.0%
PA.23 10
th
Step running time 0.0~6553.5s(h) 0.0~6553.5 0.0s
PA.24 Multi-step speed 11 -100.0~100.0% -100.0~100.0 0.0%
PA.25 11
th
Step running time 0.0~6553.5s(h) 0.0~6553.5 0.0s