EN
SAF-MI-LBK-SBV-multi-v2.0-print-26000041 |© 2020-2021 Inxpect SpA Installation instructions 15
Part Description
E Micro-USB port for connecting the PC and communicating with the Application name
application
F Micro-USB port (reserved)
G Fieldbus status LEDs (Ethernet)
H Ethernet port with LEDs for connecting the PC and communicating with the
Application name application
I Power supply terminal block
J Power supply LEDs (steady green)
K CAN bus terminal block for connecting the first sensor
L DIP switch to turn on/off the bus termination resistance:
l On (default) =resistance included
l Off = resistance excluded
M CPU LEDs:
N Ethernet Fieldbus port n. 1 with LEDs
O Ethernet Fieldbus port n. 2 with LEDs
LBK-C22 and ISC-B01 system status LED
The LEDs are each dedicated to a sensor, and can display the following statuses:
Status Meaning
Steady green Normal sensor function and no motion detected
Orange Normal sensor function and some motion detected
Flashing red Sensor in error
Steady red System error
Flashing green Sensor in boot status
LBK-C22 inputs and outputs status LED
The meaning of the LEDs when they are on is as follows:
LED Meaning
Safety output Energized relay (closed contact)
Auxiliary output Energized relay (closed contact)
Digital input High logic level (1)
LBK-S01 sensors
C
Part Description
A Sensor
B Screws for fastening the sensor at a specific inclination
C Perforated bracket for installing the sensor on the ground or on the wall