2.2.3. Characteristics and Special precautions for oxygen detectors
When the sensor is powered up or the measurement cell is replaced, it takes between 30 and
60 minutes for the measurement to stabilise at 20.9% v/v in pure ambient air.
The use of an oxygen-rich atmosphere (> 25%) can compromise safety.
3. MARKINGS
3.1. Explosion-proof safety version : OLC20d and OLCT20 d
OLDHAM Arras
0080
OLC20d or OLCT20d
II 2GD
IP66
EEx dIIC T6 (85°C)
INERIS 01ATEX0004X
Do not open when powered.
Serial number, year of manufacture
3.2. Explosion-proof safety version: OLC20d High temperature HT
OLDHAM Arras
0080
OLC20d
II 2G
EEx d IIC T4 AmbT -25°C + 110°C
EEx d IIC T3 AmbT -25°C + 180°C
EEx d IIC T2 AmbT -25°C + 200°C
INERIS 01ATEX0004X
Do not open when powered.
Serial number, year of manufacture
3.3. Intrinsic safety version: OLCT20 i
OLDHAM Arras
0080
OLCT20i
II 1 GD
IP66
EEx ia IIC T4 (T135°C)
INERIS 01ATEX0004X
Do not open when powered
Serial number, year of manufacture