even with the housing opening. See Figure 8-9. After the membrane has been fully inserted
you may then disregard the bag.
6.5 Before twisting the housing cap back on, make sure the O-ring is seated at the end of the
membrane housing as shown in figures 8 and 9. This is very important to avoid leaking
and damage to the O-ring.
6.6 Place the membrane housing cap back on and hand tighten it, then use the housing wrench
to tighten it another ¼-½” of a turn. Do not over tighten.
6.7 DO NOT reconnect the tubing to the fitting on the cap at this point (will be done in system
start up).
Step 7: Tubing Hook Up (model specific sub-steps are marked with *)
7.1 See figure Sample Installationand figures of system top view, and note connection points A-
B, C-D, E-F, and G-H.