Chapter4 SCPI Command description
4.1 IEEE488.2 common commands
*CLS
This command clears the following registers
Standard event register
Query event register
Operation event register
Status byte register
Error code
Command syntax*CLS
Parameter: None
*ESE
This command can set the parameter of standard event enable register. Setting parameter
can determine which bit of standard event register is 1 and the byte will enable ESB of status
byte register is 1.
Command syntax*ESE <NR1>
Parameter: 0~255
The value when power onRefer to *PSC command
Example*ESE 128
Query syntax*ESE
Returned parameter<NR1>
The bit definition of the standard event enabled register
Bit Position 7 6 5 4 3 2 1 0
Bit name PON not used CME EXE DDE QYE not used OPC
Bit weight 128 32 16 8 4 1
PON Power-on
CME Command error
EXE Execution error
DDE Device-dependent error
QYE Query error
OPC Operation complete
*ESE?