SCPI Command Description
Copyright© Itech Electronics Co., Ltd. 20
SYSTem:COMMunicate:LAN:CURRent:DGATeway
This command is used to set gateway of power supply.
Command syntax
SYSTem:COMMunicate:LAN:CURRent:DGATeway
Arguments
<STR>
Unit
None
*Reset Value
192.168.0.1
Example
SYST:COMM:LAN:CURR:DGAT "192.168.0.1"
Query syntax
SYSTem:COMMunicate:LAN:CURRent:DGATeway?
Returns
<STR>
SYSTem:COMMunicate:LAN:CURRent:SMASk
This command is used to set the subnet mask of power supply.
Command syntax
SYSTem:COMMunicate:LAN:CURRent:SMASk
Arguments
<STR>
Unit
None
*RST
255.255.255.0
Example
SYST:COMM:LAN:CURR:SMAS "255.255.255.0"
Query syntax
SYSTem:COMMunicate:LAN:CURRent:SMASk?