EasyManuals Logo

ITech IT6512C Manual

ITech IT6512C
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background image
Output Commands
Copyright© Itech Electronics Co., Ltd. 36
[SOURce:]VOLTage:PROTection:STATe
This command is used to set over voltage protection state.
Command syntax
[SOURce:]VOLTage:PROTection:STATe <bool>
Arguments
ON|OFF|1|0
Query syntax
[SOURce:]VOLTage:PROTection:STATe?
Returns
0|1
[SOURce:]VOLTage:PROTection[:LEVel]
This command is used to set voltage value of OVP.
Command syntax
[SOURce:]VOLTage:PROTection[:LEVel] <MINimum|MAXimum|NRf>
Arguments
MINimum|MAXimum|NRf
Unit
V
Reset Value
MAXimum
Example
VOLT:PROT MAX
Query syntax
[SOURce:]VOLTage:PROTection[:LEVel]? [MINimum|MAXimum]
Returns
NRF
[SOURce:]VOLTage:PROTection:DELay
This command is used to set delay time for over voltage protection.
Command syntax
[SOURce:]VOLTage:PROTection:DELay <MINimum|MAXimum|NRf>

Table of Contents

Other manuals for ITech IT6512C

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ITech IT6512C and is the answer not in the manual?

ITech IT6512C Specifications

General IconGeneral
BrandITech
ModelIT6512C
CategoryPower Supply
LanguageEnglish

Related product manuals