J-200
1. From the Main Menu, press the button until you reach “PREF.”
2. Press or to enter the menu. Then press the button
until you get to the “M8” display.
3. Press or to select and toggle between “ON” and “OFF.”
When ON, the poll cycles can vary between 30, 60, 90 or 120
minutes apart.
When OFF, the poll cycles are 30 minutes apart.
11.9 Utilities
This menu allows you to perform a GFCI Trip Test. A GFCI is an
important safety device and is required equipment on a spa installation.
Your spa is equipped with a GFCI protection feature (UL rated systems
only). The procedure that follows should be done at the time of
installation to verify that the GFCI is connected correctly.
The installer should cause the GFCI Trip Test to occur by initiating it. The
GFCI should trip within a few seconds and the spa should shut down. If it
does not, shut down the power and manually verify that a GFCI breaker
is installed and that the circuit and spa are wired correctly. Verify the
function of the GFCI with its own test button. Restore power to the spa
and repeat the GFCI Trip Test.
Once the GFCI is tripped by the test, reset the GFCI and the spa will
operate normally from that point. You can verify a successful test by
navigating through the programming menu. PASS should appear after
the temp button is pressed from the GFCI screen.
A. GFCI Test Trip
1. From the Main Menu, press the button until you reach “UTIL.”
2. Press or to enter the menu. The display will show “INFO.”
3. Press the button until you reach “GFCI.”
4. Pressing or will display either or .
5. Press the button until you reach “TRIP.”
6. Pressing or will display . This will activate the trip
feature. If the GFCI does not trip, the display will show the GFCI
Failure message, page 53.
7. Press the button to accept the change and return to the GFCI menu.
After a few minutes the display will revert back to the Main Menu.
B. Resetting the GFCI Trip
1. From the Main Menu, press the button until you reach “UTIL.”
2. Press or to enter the menu. The display will show “INFO.”
3. Press the button until you reach “GFCI.”
4. Pressing or will display either .
5. Press the button until you reach “TRIP.”
6. Press the button until you reach “RSET.”
7. Press the button to accept the change and return to the GFCI
menu. After a few minutes the display will revert back to the Main
Menu.
Note: The “RSET” menu will only appear if a GFCI test has been passed.