2-pumps.
TRANSFORMER
SPA LIGHT
O
3
optional CD Ozone
Circ.
Pump
N
L
N
L
N
N
N
N L
L1 L2
N L N L
L
L
L
L
PUMP 1
PUMP 2
LO
HI
HI
GRN
US / Canada 60 Hz Power Connections
240 VAC 60 Hz, 1-Phase; USE COPPER CONDUCTORS ONLY, WIRE SIZE MUST BE
APPROPRIATE PER NEC AND/OR LOCAL CODES
*
This device complies with Part
15 of the FCC rules. Operation is
subject to the following two
conditions:
1. This device may not cause
harmful interference.
2. This device must accept any
inteference received including
interference that may cause
undesired operation.
STEREO
*
(optional)
20A, 250 V, SC-20
Temp. Sensor
HI-Limit/Freeze Sensor
Flow Switch
Heater
5.5 kW
JP1
4
2
3
1
6 5
8 7
Logic Jumper Settings for all Domestic 60 Hz Models:
JP1 1-2 ON = 40 A Logic (Overrides 60A Logic)
JP1 1-2 OFF = 50 A Logic
JP1 5-6 ON = 60 A Logic (J-345 w/3.56 Chip Only)
JP1 5-6 OFF = 40 or 50A Logic (3.56 Chip Only)
JP1 7-8 ON = C Temperature Display
JP1 7-8 OFF = F Temperature Display