Page 72
J-400
= Settings 3 Menu Icon: Press button B to access the “Settings
3” Submenus.
= Previous Icon : Press button D to go to the previous menu.
13.1 Programming the Primary Filter Cycle
1. To program the Primary Filter cycle
press button A. This cycle is mainly
used to alter the pre-programmed
12-hour running period of the
circulation pump. The 12-hour cycle
is from 12:00 AM to 12:00 PM. (If
you would like to leave the circulation
pump as is, then skip this section).
Upon entering the Primary submenu the “Start Time” will
be selected (Figure C).
2. Press the Left or Right button on the Quad Keypad to choose the
hour you want the circulation pump to start running.
Note: If you are using a standard 12-hour period, you will see the hour
displayed as “1PM.” For the 24-hour period it will read “1300.”
3. Now you will need to adjust the
“Duration” (Figure D) of the cycle.
Press the Down button to select
“Duration.” Press the Left or Right
button on the Quad Keypad to make
adjustments in increments of 1 hour.
Press the Splash button on the Quad
Keypad to save hour and duration
selections and return to the Settings 2 Main Menu (Figure B,
pg. 71).
Summer Logic: In warm weather, the water temperature in the spa
may exceed the set temperature. This condition may occur due to
heat transference from the lter/circulation pump and jets pumps.
If the water temperature is higher than 95°F (35°C) and rises two
degrees above the set temperature, a “Summer Logic” condition
occurs that deactivates the lter/circulation pump and CLEARRAY™.
This safety feature cannot be altered! The lter/circulation pump and
CLEARRAY™ will remain off until the water temperature cools to the
set temperature (except between 9am-11am when the lter/circulation
pump runs for it’s mandatory 2 hour cycle.) To help prevent a “Summer
Logic” condition, it may be necessary to reduce lter/circulation pump
cycles run times in warm weather.
3
PRIMARY
Start Time
Duration
Start Time
1PM
Select
3
Press to Save
Figure C
PRIMARY
Start Time
Duration
Duration
12hr
Select
Press to Save
3
Figure D