22. SYSTEM FLAG LIST
You can use the system flags as Boolean valuables. If conditions are met, “1(true) is automatically
assigned to a system flag. If conditions are not met, “0” (false) is assigned. You can refer to the
assigned values whenever necessary.
No.
Identifier
Description
Condition “1” (True)
01
#FisCOM1
Existence of COM1 received data
Exists
02 #FltCOM1
Comparison command (cmpCOM) result of
COM1 received data
Constant > Receive data
03 #FeqCOM1
Comparison command (cmpCOM) result of
COM1 received data
Constant = Receive data
04 #FgtCOM1
Comparison command (cmpCOM) result of
COM1 received data
Constant < Receive data
05 #FtimeOutCOM1
Comparison command (cmpCOM) timeout of
COM1 received data
Timeout
06
#FisCOM2
Existence of COM2 received data
Exists
07 #FltCOM2
Comparison command (cmpCOM) result of
COM2 received data
Constant > Receive data
08 #FeqCOM2
Comparison command (cmpCOM) result of
COM2 received data
Constant = Receive data
09 #FgtCOM2
Comparison command (cmpCOM) result of
COM2 received data
Constant < Receive data
10 #FtimeOutCOM2
Comparison command (cmpCOM) timeout of
COM2 received data
Timeout
11
#FisCOM3
Existence of COM3 received data
Exists
12 #FltCOM3
Comparison command (cmpCOM) result of
COM3 received data
Constant > Receive data
13 #FeqCOM3
Comparison command (cmpCOM) result of
COM3 received data
Constant = Receive data
14 #FgtCOM3
Comparison command (cmpCOM) result of
COM3 received data
Constant < Receive data
15 #FtimeOutCOM3
Comparison command (cmpCOM) timeout of
COM3 received data
Timeout
30 #FinitMecError
Mechanical initialization command error
status
Mechanical initialization error
31
#FcameraError
Camera data acquisition error status
Error
32 #FtakeZError
Z height adjustment (takeZWadj) acquisition
error status
Error
33
#FlMoveOutRange
Range status of relative move command
Out of range
34 #FlMoveStop
Conditional stop status of relative move
command
Stopped by the stop
condition
35 #FcheckPosError
Result of the position discrepancy detection
command
Position discrepancy error
36
#FdataInBCDError
Error status of dataInBCD command
Error
60
#FstartSW
Start switch
ON (pressed)
61
#FincSW
Program number selection key (+)
ON (pressed)
62
#FdecSW
Program number selection key ()
ON (pressed)
118

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Janome JR3203N-AC and is the answer not in the manual?

Janome JR3203N-AC Specifications

General IconGeneral
BrandJanome
ModelJR3203N-AC
CategorySewing Machine
LanguageEnglish

Related product manuals