−97 −
5. Press switch 8 in the third screen of sewing common data setting.
Reverse feed control lever adjustment screen (LZ-2290A-SR only)
1. Set the reverse feed control lever to the free state and adjust so that the numeric value is among
22 to 33.
(Caution) When the adjustment is completed, turn the power OFF since it is not possible to move
from the reverse feed control lever adjustment screen to the other screen.
* For the detailed adjusting procedure, refer to 4.-(6) Adjusting/assembling the reverse feed control lever
(A-SR only)
3) Sewing management information
For the sewing management information, there are the operator level and the maintenance personnel level.
[Maintenance personnel level]
Press switch 5 in the information screen.
[Maintenance personnel level]
Press switch 5 for approximately three seconds in the information screen.
Pictograph on the left end of the sewing management information is shown in reverse video.
Sewing management information screen (Maintenance personnel level)
Error record display 6
Maintenance management
function 4
Existing value of the lever is displayed.