(No.MA094B)1-13
SECTION 4
ADJUSTMENT
4.1 Adjustment method
Test instruments required for adjustment
(1) Digital oscilloscope (100MHz)
(2) Frequency counter meter
(3) Electric voltmeter
(4) Wow & flutter meter
(5) Test tapes
VT724 : For DOLBY level measurement
VT739 : For playback frequency measurement
VT712 : For wow flutter & tape speed measurement
VT703 : For head azimuth measurement
(6) Torque gauge : Cassette type for CTG-N (Mechanism adjustment)
Standard volume position
Balance and Bass, Treble volume, Fader : Center (Indication "0")
Loudness, Dolby NR, Sound, Cruise : Off
Volume position is about 2V at speaker output with following conditions, Playback the test tape VT721.
Measuring conditions (Amplifier section)
AM mode 999kHz/62dB, INT/400Hz, 30% modulation signal on receiving.
FM mono mode 97.9MHz/66dB, INT/400Hz, 22.5kHz deviation pilot off mono
FM stereo mode 1kHz, 67.5kHz dev. pilot 7.5kHz dev.
Output level 0dB (1µV,50Ω/open terminal)
Power supply voltage : DC14.4V (11V to 16V)
Load impedance : 4 Ω (4 Ω to 8 Ω allowance)
Line out : 1.0V/20kΩload (250 nWb/m)