– 8
Completely empty the descaling solution after 8
hours. A small amount of the solution will remain in
the boiler. Therefore, you should rinse the boiler
two to three times with cold water to remove any
residues of the descaler.
Illustration
Completely empty the steam boiler to remove exist-
ing water.
Note
The floor cleaning cloth and the terry cloth cover have
been pre-washed and can be used immediately for
working with the steam cleaner.
You can wash dirty floorcloths and terry cloth cov-
ers in the washing machine at 60°C. Do not use a
liquid softener as this would affect the ability of the
cloths to pick up dirt. You may tumble dry the
cloths.
Often, failures have simple causes and you can do the
troubleshooting yourself using the following overview. If
you are in doubt or if the failure is not listed here please
contact the authorized customer service.
Decalcify appliance.
Refill water
The steam button is secured with the child lock.
Push the child lock at the top (steam button un-
locked).
Remove the accessory from the steam nozzle.
Clean the nozzle insert.
Briefly switch on the appliance.
Reattach the accessory to the steam nozzle.
Do not tilt the appliance too much to the side during
cleaning work (max. angle 30°).
Subject to technical modifications!
Care of the Accessories
Troubleshooting
Decreased steam amount
Appliance is decalcified.
Steam decreases during the work / no steam
No water in the water reservoir.
The steam button cannot be pushed.
Steam nozzle is plugged
High water output
Technical specifications
Electrical connection
Voltage 220-240
1~50-60
V
Hz
Protection class IP X4
Protective class I
Performance data
Heating output 1200 W
Operating pressure max. 0,3 MPa
Heating time 3 Minutes
Steam volume
Continuous steaming 35 g/min
Steam push max. 80 g/min
Dimensions
Volume
Boiler capacity
250 ml
Filling quantity 200 ml
Length 321 mm
Width 127 mm
Height 186 mm
Weight (without accessories) 1,5 kg
12 EN