4. Press SELECT again to show the following
RECHARGE display.
EXAMPLE: Set to 4 days maximum between
regenerations.
Maximum Days Between Regenerations: The face
plate timer automatically controls regeneration fre-
quency. This provides the greatest operating efficiency,
and under most conditions this feature will be left in its
default mode. However, you can modify this feature if
you want to force a regeneration every set number of
days. For example, if your water supply contains iron
and you want the softener to regenerate at least once
every few days to keep the resin bed clean, set the dis-
play as typically shown above. Setting is available from
1 to 6. Press SELECT to return to the present time is
play.
5. Press SELECT to show the 97% display.
97% Feature: The 97% Feature can save salt and
water by regenerating when 97% of the softener's
capacity has been used up. With this feature ON, the
regeneration can occur at any time (whenever the sys-
tem has reached 97% of its capacity). The default is
OFF. If this feature is desired, turn it on by pressing the
UP button.
IntelliSoft is a new Kenmore exclusive technology built
into your system's electronic control. IntelliSoft
ensures that your softening system provides you with
the most accurate salt dose to fit your water use
needs, providing you with industry leading water and
salt savings.
6. Press SELECT to show the 12 HOUR display.
12 or 24 hour clock: All time displays are shown in
standard clock time (1 to 12 PM; and 1 to 12 AM) at
the 12 hr default setting. If Military time displays are
desired, set to 24 hr by pressing the UP button.
WATER FLOW THROUGH THE SOFTENER
If soft water is in use, the water flow bars continually
scroll across the display. The bars scroll slowly when
water flow is slow, and move faster as water flow increas-
es. The flow bars do not show when all faucets and water
using appliances are off.
DAY
RECHARGE
Default Display
i I'=1- I-
N I- -
RECHARGE
ICI ii
TIME
Flow bars scroll when
soft water is in
Example:
Set to 4 Days Maximum
Between Regeneration
q7
RECHARGE
_UL _
II II
TIME
FIG. 37
Questions? Call The Kenmore Water Line 1-800-426-9345
24

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kenmore IntelliSoft 350 Series and is the answer not in the manual?

Kenmore IntelliSoft 350 Series Specifications

General IconGeneral
BrandKenmore
ModelIntelliSoft 350 Series
CategoryWater Dispenser
LanguageEnglish

Related product manuals