44 PFB-BA-e-1322
10 Data output RS232
You can print out weighing data via the RS 232C interface.
The following conditions must be met to provide successful communication between
the weighing balance and the printer.
Use a suitable cable to connect the weighing balance to the interface of
the printer. Faultless operation requires an adequate KERN interface
cable.
Communication parameters (baud rate, bits and parity) of balance and
printer must match.
10.1 Technical data
Connection 9 pin d-subminiature bushing
Baud rate 9600
Parity 8 bits, no parity
10.2 Pin allocation of balance output bushing:
5 1
9 6
Pin 2 input
Pin 3 output
Pin 5 signal earth