1 - SAFETY WARNINGS
ORIGINAL INSTRUCTIONS - important safety
instructions. Follow the instructions since in-
correct installation can lead to severe inquiry!
Save these instructions.
Read the instructions carefully before proceeding
with installation.
The design and manufacture of the devices
making up the product and the information in
this manual are compliant with current safety
standards. However, incorrect installation or
programming may cause serious injury to tho-
se working on or using the system. Complian-
ce with the instructions provided here when
installing the product is therefore extremely
important.
If in any doubt regarding installation, do not pro-
ceed and contact the Key Automation Technical
Service for clarications.
According to European standards, the con-
struction of a motorized barrier must comply
with the provisions of Directive 2006/42/EC
(Machinery Directive) including the standards
EN 12445; EN 12453 and EN 13241-1, which en-
sure the conformity of the automation.
Therefore, nal connection of the automation
system to the electrical mains, system testing,
commissioning and routine maintenance must be
performed by skilled, qualied personnel, in obser-
vance of the instructions in the “Testing and com-
missioning the automation system” section.
The aforesaid personnel are also responsible for
the tests required to verify the solutions adopted
according to the risks present, and for ensuring
observance of all legal provisions, standards and
regulations, with particular reference to all requi-
rements of the EN 12445 standard which establi-
shes the test methods for testing barrier automa-
tion systems.
Before starting installation, perform the fol-
lowing checks and assessments:
ensure that every device used to set up the au-
tomation system is suited to the intended system
overall. For this purpose, pay special attention to
the data provided in the “Technical specications”
section. Do not proceed with installation if any one
of these devices is not suitable for its intended pur-
pose;
check that the devices purchased are su󰀩cient to
guarantee system safety and functionality;
perform a risk assessment, including a list of the
essential safety requirements as envisaged in An-
nex VII of the Machinery Directive, specifying the
solutions adopted. The risk assessment is one
of the documents included in the automation sy-
stem’s technical le. This must be compiled by a
professional installer.
Considering the risk situations that may arise
during installation phases and use of the pro-
duct, the automation system must be installed
in compliance with the following safety pre-
cautions:
never make modications to any part of the auto-
mation system other than those specied in this
manual. Operations of this type can only lead to
malfunctions. The manufacturer declines all liabi-
lity for damage caused by unauthorised modica-
tions to products;
if the power cable is damaged, it must be replaced
by the manufacturer or its after-sales service, or in
all cases by a person with similar qualications, to
prevent all risks;
do not allow parts of the automation system to be
immersed in water or other liquids. During instal-
lation ensure that no liquids are able to enter the
various devices;
should this occur, disconnect the power supply
immediately and contact a Key Automation Servi-
ce Centre. Use of the automation system in these
conditions may cause hazards;
never place automation system components near
to sources of heat or expose them to naked lights.
This may damage system components and cause
malfunctions, re or hazards;
The drive shall be disconnected from its po-
wer source during cleaning, maintenance and
when replacing parts. If the disconnect device
is not in a visible location, a󰀩x a notice sta-
ting: “MAINTENANCE IN PROGRESS”:
connect all devices to an electric power line equip-
ped with an earthing system;
the product cannot be considered to provide e󰀨ec-
tive protection against intrusion. If e󰀨ective protec-
ATTENTION !
ATTENTION ! ATTENTION !

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Key Automation ALT3KF and is the answer not in the manual?

Key Automation ALT3KF Specifications

General IconGeneral
BrandKey Automation
ModelALT3KF
CategoryOther
LanguageEnglish

Related product manuals