Operating Instructions
15
CO Alarm Response Time
Never restart the source of a CO problem until it has
been fixed. NEVER IGNORE THE ALARM!
The CO sensor meets the alarm response time requirements of
EN50291-1:2010 Standard alarm times are as follows:
This carbon monoxide alarm is designed to detect
carbon monoxide gas from ANY source of combus-
tion. It is NOT designed to detect any other gas.
It can be possible to arrange for a CO inspection of your
home or property, but some inspectors may charge for this
service. Kidde will not pay for or reimburse the owner or
user of this product for any repair or dispatch calls related
to the alarm sounding so it is advisable to inquire about
fees prior to having such a service performed.
NOTE: Before activating the battery carrier tamper resist feature,
make sure a fresh battery is installed in the unit and that the battery
carrier is properly closed. If the battery carrier tamper resist feature
is activated while the battery carrier is open, the battery carrier will
not close and the unit will be inoperable.
T
o deactivate the battery carrier tamper resist, in order to change the
smoke alarm battery, remove the unit from the trim plate (see Smoke
Alarm Tamper Resist Feature if activated), and locate the small cut-out in
the middle of the product label. Using a screwdriver, or similar tool,
slide the switch towards the bottom of the product label. The battery
carrier can now be opened and the battery changed.
Parts per Million
(PPM) of CO
Time un l Alarm
50 60 – 90 minutes
100 10 – 40 minutes
300 Must alarm in less than 3 minutes