28
Power: Three AA batteries (supplied)
Sensor: Electrochemical carbon monoxide
sensor
Humidity Range: 10% to 90% rh (non-condensing)
Accuracy: +/- 20% +15 PPM
Temperature: Operating range 40°F (4.4°C) to
100°F (37.8°C)
Mounting: Accessories supplied for wall
mounting
Alarm: 85+ dB at 10' @ 3.4 ± 0.5 KHz
pulsing alarm
LED Operation: Flashing red LED every 30 seconds
accompanied by an alarm chirp
indicates a system problem
Flashing green LED every 30 seconds
indicates proper operation
Pulsing red LED indicates presence
of CO
LCD Display: Digital readout 30-999 PPM
Battery charge indicator (fuel gauge)
Sensor malfunction icon
Battery
Replacement: Unit displays Err or Lb and an empty
fuel gauge icon. Replace the three
AA batteries with one of the
following approved brands.
• Duracell MN1500
• Energizer E91
• Camelion Mignon LR6-AM3-1.5
• Rayovac 815
Product Specifications
27
Q.
How many CO alarms do I need in my house?
How many square metres will one CO alarm cover?
A.
We recommend you place CO alarms near the sleeping
area(s). If you have a multi-level home, you should place a CO
alarm on each level of the home. A good rule of thumb for the
number and placement of CO alarms for your particular home is
to place CO alarms near smoke alarms that have been installed to
meet current building code requirements.
Generally, one CO alarm can be adequate for 300 square metres
of living space. The most important determination for the number
of alarms needed is whether an alarm can be heard in all sleeping
areas.
Q.
Do I have to press the test button to get a CO
reading
?
A.
No. Your Nighthawk CO alarm continuously monitors the air
for carbon monoxide. An updated reading is shown on the digital
display every 30 seconds. If there is no CO present, the digital
display will show a zero. The CO alarm will alert you to the
presence of CO automatically. To test the internal components
and circuitry of your CO alarm, press the test/reset button.
Frequently Asked Questions
Benelux Guide 21/8/01 2:15 pm Page 27

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Kidde Nighthawk and is the answer not in the manual?

Kidde Nighthawk Specifications

General IconGeneral
BrandKidde
ModelNighthawk
CategoryCarbon Monoxide Alarm
LanguageEnglish

Related product manuals