3. Other Alarm Visual and Audible Indicators
Operational Mode Visual Indications Audible Indications Action/Note:
Normal (standby) AC power: Green LED on continuously
during light conditions, or blink every
60 sec during dark conditions.
DC power: Green LED blink approx
every 60 sec.
Test (button press when
no alarm condition is
present)
• 4 patterns of Red/Amber/Green.
• Test: Red LED blinks in time with alarm
pattern. Strobe ashes every second
during smoke alarm, and 4 times every
5 seconds during CO alarm.
• Green LED fade on/o at test complete
• Button press sound
• Voice: "Testing, this is very loud.
Press now to cancel test. 5, 4, 3, 2, 1."
• 3 long beeps, Voice "Fire!",
3 long beeps, 4 quick beeps, Voice
"Warning, Carbon Monoxide,"
4 quick beeps, Voice "Test
Complete," Power on/reset sound.
• Voice "Test Canceled" if button
pushed before test sequence
begins.
Perform Test/Hush button press
once a week to verify proper alarm
operation
* Push/release button before the
countdown ends to cancel test.
Smoke or CO Alarm
Memory (unit has
experienced a smoke or
CO alarm event within the
last hour)
Red and Amber LED alternate on 1 sec,
every 10 sec.
After button push: "Smoke previously
detected" or "Carbon Monoxide
previously detected" only on the
initiating alarm unit.
Push test button to clear Alarm
Memory. NOTE: standard test
sequence will follow. (Push/release
button again to cancel test).
Smoke Alarm Hush Mode,
(Hush
®
Control)
Red LED blinks every 2 sec. After button push: "Hush Mode Acti-
vated." Smoke alarm pattern stops.
(If there is too much smoke to allow
Hush: Voice "Too Much Smoke, Alarm
cannot be Hushed" Smoke alarm
pattern continues.)
This feature is to be used only
when a known alarm condition,
such as smoke from cooking,
activates the alarm.
CO alarm reset None After button push: CO alarm pattern
stops.
Unit is conrming if CO is present
or if it experienced a nuisance
situation. Re-alarm means danger.
Move to fresh air and call 911.
Smoke Alarm Hush Mode
Canceled
None Voice message "Hush Mode
Canceled."
When smoke levels drop below the
alarm threshold, the voice message
"Hush Mode Canceled" will occur .
Initiating Alarm,
(Multiple alarms in an
interconnected system)
Green LED blinks once per sec indicating
that this is the unit initiating the alarm
in an interconnected, multiple alarm,
system. Strobe ashes in smoke or CO
alarm pattern.
Unit in either Smoke or CO alarm
mode.
During alarm, the Initiating alarm
green blinks will occur in between
the red blinks.